trane voyager 3 dimensions

Unitary Rooftop Systems Voyager III

trane voyager 3 dimensions

Packaged Rooftop Air Conditioners

Through the years, Trane has designed and developed the most complete line of Packaged Rooftop products available in the market today. Trane was the first to introduce the Micro—microelectronic unit controls—and has continued to improve and revolutionize this design concept.

The ReliaTel™ control platform offers the same great features and functionality as the original Micro, with additional benefits for greater application flexibility.

The Voyager™ Commercial line offers 27½ to 50 ton, 60 Hz and 23 to 42 ton 50 Hz models. Both 50 and 60 Hz models come in a choice of five sizes to meet the changing demands of the commercial rooftop market.

Trane customers demand products that provide exceptional reliability, meet stringent performance requirements, and are competitively priced. Trane delivers with Voyager Commercial.

Voyager Commercial features cutting edge technologies: reliable 3-D™ Scroll compressors, eStage for premium efficiency, Trane engineered ReliaTel controls, computer-aided run testing, and Integrated Comfort™ Systems.

So, whether you’re a contractor, the engineer, or an owner you can be certain Voyager Commercial Products are built to meet your needs.

For Technical Specifications, please refer to the Catalog or Installation documents on the Literature tab.

If you are interested in CAD template drawings for Trane products contact your local Trane sales office and work with a sales representative. Your sales representative can help you obtain the right unit selection and drawing for your application.

Sales Brochure

  • RT-PRC033H-EN_022016

Installation, Operation and Maintenance (IOM)

  • RT-SVX34L-EN_02172016

ComfortSite Login

Trane ComfortSite is an extranet site designed to save you time. With your secure login, you can:

  • Order Equipment, Parts, Literature and track Order Status
  • View product literature
  • Register for Training programs
  • Complete Warranty requirements online
  • Search for specific Product Information
  • Use interactive Product Support functions
  • View and print invoices through Account Track Online

Trane Connect

This is the login for Trane® Connect™ and other Trane® commercial applications. Trane® Connect™ is our secure, cloud-based customer portal to access your building systems to remotely monitor and manage building systems, and conduct routine maintenance.

  • Looking for Parts?
  • Safety Data Sheets
  • Customer Login

Intelligent VAV Systems

  • Water-Cooled Chillers
  • Air-Cooled Chillers
  • Modular Chillers
  • Cold Gen Scroll Chillers
  • Chiller Heaters
  • Packaged Units & Split Systems
  • CoolSense® Integrated Outdoor Air Systems

Zoned Rooftop Systems

Rooftop units.

  • Split Systems
  • Self-Contained Units
  • Water Source Heat Pumps
  • Dedicated Outdoor Air Units
  • Air-to-Water Heat Pumps
  • Electrification of Heat
  • Controls & Building Automation Systems
  • Controls for Large Buildings & Campuses
  • Controls for Small Buildings
  • Wireless Systems
  • Lighting Solutions
  • Controls Solutions for Light Commercial Contractors
  • Cybersecurity
  • Air Handling
  • Sensible-Cooling Terminal Unit
  • VAV (Variable Air Volume) Units
  • Performance Air Handlers
  • Air Handler Accessories
  • Unit Heaters
  • Air Rotation Units
  • Thermal Energy Storage
  • Thermal Battery Systems
  • Thermal Energy Storage Solutions
  • Design & Analysis Software
  • TRACE® 3D Plus
  • Trane® Design Assist™
  • Trane® Select Assist™ (Formerly known as TOPSS™)
  • Calculators & Charts
  • View All Design & Analysis Tools
  • Trane Drives
  • TR200 Variable Frequency Drive
  • Indoor Environmental Quality (IEQ) Solutions
  • Indoor Air Quality
  • Thermal Comfort
  • Our 3-Step Process
  • IAQ Services
  • Training & Support
  • Training & Support Close
  • Education & Training
  • Trane HVAC Education & Training
  • Trane University
  • Trane Education Center
  • Design & Analysis Tools Training
  • Engineers Newsletters & Engineers Newsletters Live!
  • Engineer & Contractor Support
  • Engineering Support
  • Contractor Support
  • Trane C.D.S. Software Support
  • BIM-Revit Library
  • Financing Support
  • OMNIA Partners
  • Anticipation Discount Program
  • Total Cost of Ownership Analysis
  • Energy Savings Performance Contracting (ESPC)
  • Energy Savings Contracting
  • Cooperative and Group Purchasing
  • Legislation and Incentives Resource Center
  • View Legislation and Incentives Resource Center
  • Trane Equipment Rebate Finder
  • Commercial Real Estate
  • Data Centers
  • Food & Beverage
  • Federal Government
  • Fulfillment Centers
  • Grocery & Supermarkets
  • Higher Education
  • Hospitality
  • Indoor Agriculture
  • Life Sciences
  • Local Government
  • Restaurants
  • Retail Buildings
  • National Accounts
  • Locate a Sales Office
  • Trane Newsroom
  • Customer Stories
  • Press Releases
  • Region Close

Decarbonization

Discover which experts from Trane will be presenting and what topics they will cover at the upcoming ASHRAE Winter Conference and AHR Expo

CONTACT A TRANE EXPERT

Value through the roof, adaptable, flexible rooftop solutions for virtually any building.

Trane rooftop units offer superior indoor air quality, industry leading energy efficiency, hassle-free installation – everything you need for new construction or replacement projects.

Nahaufnahme eines Stromzählers

Energy Efficient

Superior EER and IEER ratings mean outstanding occupant comfort plus energy efficient operation for single or multiple zones.

rooftop-units-circle2.jpg

Future-Ready

Ability to connect with building automation systems for enhanced monitoring, maintenance and performance optimization.

rooftop-units-circle3.jpg

Flexible Features

From ready out-of-the-box to design-build customization with a variety of premium features and accessories. Can be configured for specific applications whether a corner retail store or a large data center.

Metal industrial air conditioning vent. HVAC. Ventilation fan.

Engineered for durability and reliability with quality components backed by an outstanding Trane warranty.

Small to Large Commercial Rooftop Units: 2 - 150 Tons

25 tons and under.

trane voyager 3 dimensions

At a glance

  • Capacity Range: 2-5 tons
  • Types: Gas/Electric, Electric/Electric, Heat Pump, Hybrid Dual Fuel
  • Refrigerant: R-410A
  • Efficiency Tiers: Standard & High
  • Unit Controls: Electromechanical

trane voyager 3 dimensions

Foundation® Rooftop Units

  • Capacity Range: 3-25 tons
  • Types: Gas/Electric & Electric/Electric
  • Efficiency Tiers: Standard
  • Unit Controls: Electromechanical 

trane voyager 3 dimensions

Precedent® Rooftop Units

  • Types: Gas/Electric, Electric/Electric
  • Efficiency Tiers: Standard, High and Ultra-High
  • Unit Controls: Symbio 700 (6-25), ReliaTel or Electromechanical (3-5)

trane voyager 3 dimensions

Precedent® Heat Pump Rooftop Units

  • Types: Heat Pumps & Hybrid Dual Fuel
  • Unit Controls: Symbio 700 (12.5-25 tons)

trane voyager 3 dimensions

Trane® Light Commercial Replacement Solutions

Emergency replacement needs? Your local Trane Light Commercial Replacement Solutions Team is here to help with all your immediate rooftop and split system replacement needs.

  • Quick and accurate price quotes
  • Quick replacement
  • Quick fulfillment and delivery
  • Locally available equipment and accessories

20 Tons and Over

trane voyager 3 dimensions

Voyager® 3 Rooftop Units

  • Capacity Range: 27.5-50 tons
  • Refrigerant: R-410A / R-454B
  • Unit Controls: Symbio 700

trane voyager 3 dimensions

IntelliPak® Rooftop Units

A popular, dependable choice for efficient and quiet comfort with lower operating costs.  IntelliPak rooftop units set the bar for durability and value.  With a portfolio of three distinct products and industry leading efficiencies, the Intellipak product is designed to serve a range of application and regulatory needs.  

IntelliPak 1 - 20-130 Tons

IntelliPak 2 - 90-150 Tons

IntelliPak 3 - 20-75 Tons

Rooftop Systems

trane voyager 3 dimensions

Ideal for small buildings, Trane® Zoned Rooftop Systems provide cost-effective options to increase comfort and energy efficiency, while simplifying operation and maintenance. These packaged systems make advanced functionality affordable and easy for non-technical users to operate.

trane voyager 3 dimensions

Trane Intelligent VAV systems simplify the design and implementation of systems that HVAC designers typically consider complicated and time-consuming. With new technologies and optimized controls, these systems are 20% to 30% more efficient than traditional multiple-zone VAV systems.

Looking For Parts?

For General and Corporate Questions:

Contact Trane to Speak with an Expert

Comfort Solutions Heating & Cooling

Voyager® Commercial Heating and Cooling Rooftop Units

emergency commercial rooftop hvac repair, commercial hvac repair contractor, commercial hvac replacement contractor, rooftop air conditioner repair, rooftop ac unit repair, rooftop unit replacement, rooftop HVAC repair, commercial heating repair

Voyager® 2 – 12.5 – 25 Tons & Voyager® 3 27.5 – 50 Tons

Key Features:

  • Available in gas/electric, electric/electric & heat pump only for Voyager 2.
  • Dependable MERV filtration that removes contaminants as small as 0.3 microns.
  • Fast delivery to keep projects on track and sites up and running.
  • Energy-efficient performance lowers costs without sacrificing comfort.
  • Engineered for performance and durability.
  • Connected-ready to optimize HVAC performance.
  • Fully customizable.
  • Designed-in features simplify installation and service.
  • Trane quality guarantee.
  • Financing available.

Request a Quick Quote

Ultra-energy efficient comfort.

Guaranteed Quality You Can Count On

Trane’s Voyager 2 & Voyager 3 rooftop units offer sustainable HVAC solutions backed by an outstanding warranty:

• ASHRAE 90.1 and Energy Star compliant.

• Optional Trane eFlex™ variable-speed compressors and fans deliver ultra-high efficiency .

• Variable air volume (VAV) options service single- and multi-zone applications.

• 10 years on the stainless steel heat exchanger.

• 5 years parts only on the compressor.

• 5 years on low-leak economizer.

• 1 year on all standard parts

• Extended warranty options for additional peace of mind.

emergency commercial rooftop hvac repair, commercial hvac repair contractor, commercial hvac replacement contractor, rooftop air conditioner repair, rooftop ac unit repair, rooftop unit replacement, rooftop HVAC repair, commercial heating repair

The Voyager rooftop unit line features:

Choose from Voyager 2 or Voyager 3 models to meet the needs of a broad range of small, medium to large commercial buildings.

  • High-efficiency filtration removes contaminant particles as small as 0.3 microns with MERV 8, MERV 13, and up to MERV 14 filters (with Voyager 3).
  • Hot gas reheat cycles heat energy from the compressor to reduce indoor air humidity.
  • Unique coil design uses less refrigerant.
  • All-aluminum microchannel (MCHE) condenser coils provide  extra durability.
  • Foil-faced insulation edges prevent fibers from entering the airstream and clogging filters.
  • Coating options to protect against corrosion.
  • Easy chemical-free cleaning.

commercial ac replacement, commercial furnace repair, rooftop furnace, Trane commercial rooftop units, 3-ton rooftop ac unit, 5-ton rooftop ac unit, rooftop ac unit cost, 5-ton commercial rooftop HVAC, emergency commercial rooftop hvac repair

Performance and Durability You Can Rely On

12.5 – 25 Tons

Cooling, Electric/Electric & Heat Pumps.

  • The lowest total cost of ownership = low installation & maintenance costs.
  • High-efficiency options with Up to 20.1 IEER with eFlex technology cooling, gas/electric models.
  • Fastest delivery times – get it within 2 weeks.
  • Design customization with a wide variety of factory-installed options to meet the needs of unique light commercial applications.
  • Single & multi-space VAV options.
  • Dual compressors provide outstanding humidity control, light load cooling, and system backup.
  • Dependable performance with ReliaTel controls, computer-aided run testing & 3-D scroll compressors.
  • Color-coded and numbered wiring (Voyager 2) for easier installation.

Designed for maximum performance & efficiency in larger buildings.

27.5 – 50 Tons

With Voyager 3 a variety of standard and optional features offer customized HVAC solutions for larger commercial buildings:

Same footprint designed to match legacy models for plug and play replacement.

  • Ready to go out of the box design.
  • Optional Trane eStage™ compressors deliver increased full and part load efficiencies = 5 – 15% higher full load efficiencies & 15 – 25% higher part load efficiencies vs standard units.
  • Trane® Air-Fi Wireless connectivity for hassle-free installations.
  • Touchscreen Human Interface – easy access to manage & monitor performance.
  • Modulating gas heat & modulating hot gas reheat.
  • Ultra-low leak economizer.
  • Monitor outside airflow with Traq.
  • Microchannel condenser coil for exceptional heat transfer.
  • IBC & OSHPD seismic compliance.

commercial AC repair, commercial AC Replacement, commercial furnace repair, commercial furnace replacement, commercial HVAC repair estimate, emergency commercial HVAC repair, energy efficient commercial HVAC rooftop unit

Voyager is Not a One Size Fits All – Multiple Custom Options Available

Dozens of factory-installed options include:

  • Optional Trane eStage™ compressors deliver increased full and part load efficiencies on Voyager 3.
  • Trane® Air-Fi Wireless connectivity.
  • CO2 sensor wiring.
  • Fault detection diagnostics.
  • High-efficiency motors and filtration
  • Multiple-zone VAV controls and many more.

emergency commercial rooftop hvac repair, commercial hvac repair contractor, commercial hvac replacement contractor, rooftop air conditioner repair, rooftop ac unit repair, rooftop unit replacement, rooftop HVAC repair, commercial heating repair

For a hassle-free commercial heating repair or replacement, commercial air conditioning repair or replacement, or an industrial ac repair or replacement estimate, from 3-ton rooftop ac units and 5-ton rooftop ac units to 3-25+ zoned rooftop systems, contact Comfort Solutions Heating and Cooling today at 763-565-2121 , your local commercial HVAC expert.  Plus, we provide financing options through Trane® Technologies Financial Services.  In addition to rooftop repair and replacement, we specialize in split systems furnace and air conditioners, ductless splits, commercial make-up air units, infrared heaters, unit heaters, and building controls and exhaust fans.

Trane Voyager TC* User Manual

  • Trane Manuals
  • Air Conditioner
  • Voyager TC*
  • User manual

Trane Voyager TC* User Manual

  • page of 109 Go / 109

Table of Contents

  • Packaged Gas/Electric View
  • Packaged Cooling View
  • Standard Features
  • Variety of Options
  • Other Benefits
  • Voyager Factory Installed Options
  • Cooling Capacity
  • Heating Capacity
  • Air Delivery Selection
  • Dehumidification Selection
  • Psychrometric Chart
  • Model Number Notes
  • General Data — 12,5-15 Tons
  • General Data — 17,5-20 Tons
  • General Data — 25 Tons
  • General Data — 17,5 20, 25 Tons
  • Gross Cooling Capacities 12½ Tons Three Phase Standard Efficiency T/YC150D3,4,W,K
  • Gross Cooling Capacities 15 Tons Three Phase Standard Efficiency T/YC180B3,4,W,K
  • Gross Cooling Capacities 17½ Tons Three Phase Standard Efficiency T/YC210C3,4,W,K
  • Gross Cooling Capacities 20 Tons Three Phase Standard Efficiency T/YC240B3,4,W,K
  • Gross Cooling Capacities 25 Tons Three Phase Standard Efficiency T/YC300B3,4,W,K
  • Gross Cooling Capacities 12½ Tons Three Phase Standard Refrigeration System High Efficiency T/YC*151C3,4,W
  • Gross Cooling Capacities 12½ Tons Three Phase Dehumidification (Hot Gas Reheat) or TXV Option High Efficiency T/Y*D151C3,4,W
  • Gross Cooling Capacities 15 Tons Three Phase Standard Refrigeration System High Efficiency T/YC*181C3,4,W
  • Gross Cooling Capacities 15 Tons Three Phase Dehumidification (Hot Gas Reheat) or TXV Option High Efficiency T/Y*D181C3,4,W
  • Gross Cooling Capacities 17½ Tons Three Phase Standard Refrigeration Option High Efficiency T/YC*211C3,4,W
  • Gross Cooling Capacities 17½ Tons Three Phase TXV Option High Efficiency T/Y*D211C3,4,W
  • Gross Cooling Capacities 20 Tons Three Phase Standard Refrigeration Option High Efficiency T/YC*241C3,4,W
  • Gross Cooling Capacities 20Tons Three Phase TXV Option High Efficiency T/Y*D241C3,4,W
  • Gross Cooling Capacities 20Tons Three Phase Dehumidification (Hot Gas Reheat) Option High Efficiency T/Y*D241C3,4,W
  • Gross Cooling Capacities 25 Tons Three Phase Standard Refrigeration System High Efficiency T/YC*301C3,4,W
  • Gross Cooling Capacities 25 Tons Three Phase TXV Option High Efficiency T/Y*D301C3,4,W
  • Evaporator Fan Performance 12½ Tons TC*150D Downflow or Horizontal
  • Evaporator Fan Performance 12½ Tons with Gas Heat YC*150D Downflow or Horizontal
  • Evaporator Fan Performance 15 Tons TC*180B Downflow or Horizontal
  • Evaporator Fan Performance 15 Tons with Gas Heat YC*180B Downflow or Horizontal
  • Evaporator Fan Performance 17½ Tons TC*210C Downflow or Horizontal
  • Evaporator Fan Performance 17½ Tons with Gas Heat YC*210C Downflow or Horizontal
  • Evaporator Fan Performance 20 Tons TC*240B Downflow or Horizontal
  • Evaporator Fan Performance 20 Tons with Gas Heat YC*240B Downflow or Horizontal
  • Evaporator Fan Performance 25 Tons TC*300B Downflow or Horizontal
  • Evaporator Fan Performance 25 Tons with Gas Heat YC*300B Downflow or Horizontal
  • Evaporator Fan Performance 12½ Tons TCD151C Standard or TXV Refrigeration System Downflow
  • Evaporator Fan Performance 12½ Tons T*D151C Dehumidification (Hot Gas Reheat Option) Downflow
  • 3-HP Standard Motor & Drive
  • Cfm Rpm Bhp Rpm Bhp Rpm
  • Evaporator Fan Performance 12½ Tons TCH151C Standard Refrigeration System Horizontal
  • External Static Pressure (Inches of Water) .40
  • Fan Motor Heat (MBH) = 3.15 X Fan BHP
  • For Standard Evaporator Fan Speed (RPM), Reference
  • Refer to Table
  • 3-HP Standard Motor & High Static Drive Accessory
  • Bhp Rpm Bhp Rpm Bhp Rpm Bhp Rpm
  • Evaporator Fan Performance 12½ Tons with Gas Heat YCD151C Standard or TXV Refrigeration System Downflow
  • Evaporator Fan Performance 12½ Tons with Gas Heat Y*D151C Dehumidification (Hot Gas Reheat Option) Downflow
  • Evaporator Fan Performance 12½ Tons with Gas Heat YCH151C Standard Refrigeration System Horizontal
  • Evaporator Fan Performance 15 Tons TC*181C Standard or TXV Refrigeration System Downflow or Horizontal
  • Evaporator Fan Performance 15 Tons T*D181C Dehumidification (Hot Gas Reheat Option) Downflow
  • BHP RPM BHP RPM BHP RPM BHP RPM 3-HP Standard Motor & High Static Drive Accessory
  • Evaporator Fan Performance 15 Tons with Gas Heat YC*181C Standard or TXV Refrigeration System Downflow or Horizontal
  • Evaporator Fan Performance 15 Tons with Gas Heat Y*D181C Dehumidification (Hot Gas Reheat) Option Downflow
  • Evaporator Fan Performance 17½ Tons TC*211C Standard or TXV Refrigeration System Downflow or Horizontal
  • Evaporator Fan Performance 17½ Tons with Gas Heat YC*211C Standard or TXV Refrigeration System Downflow or Horizontal
  • Evaporator Fan Performance 20 Tons TC*241C Standard or TXV Refrigeration System Downflow or Horizontal
  • Evaporator Fan Performance 20 Tons T*D241C Dehumidification (Hot Gas Reheat Option) Downflow
  • Evaporator Fan Performance 20 Tons with Gas Heat YC*241 Standard or TXV Refrigeration System Downflow or Horizontal
  • Evaporator Fan Performance 20 Tons with Gas Heat Y*D241 Dehumidification (Hot Gas Reheat Option) Downflow
  • Evaporator Fan Performance 25 Tons TC*301C Standard Refrigeration or TXV System Downflow or Horizontal
  • Evaporator Fan Performance 25 Tons with Gas Heat YC*301C Standard Refrigeration or TXV System Downflow or Horizontal
  • Oversized Motor & Drive Fan Speed (Rpm)
  • Standard Motor & Drive/Fan Speed (Rpm)
  • Standard Motor & High Static Drive Accessory Sheave/Fan Speed (Rpm)
  • Standard Motor & Low Static Fan Drive
  • Static Pressure Drop through Accessories (Inches Water Column)
  • Gas Fired Heating Capacities
  • Auxiliary Electric Heat Capacity
  • Electric Heater Voltage Correction Factors (Applicable to Auxiliary Heat Capacity)
  • Air Temperature Rise Across Electric Heaters (Degrees F)
  • Hot Gas Reheat Temperature Rise
  • Reliatel Controlled Units
  • Unit Wiring with Gas Heat or Cooling (no Electric Heat)
  • Unit Wiring with Electric Heat (Single Point Connection) — Standard and Oversized Motor, Downflow & Horizontal
  • Electrical Characteristics — Compressor Motor and Condenser Motor — 60 Cycle
  • Electrical Characteristics — Evaporator Fan Motor — 60 Cycle — Standard and Oversized Motor
  • Electrical Characteristics — Combustion Blower Motor (Gas/Electric)
  • Electrical Characteristics — Power Exhaust (Cooling and Gas/Electric)
  • Unit Wiring with Cooling (no Electric Heat) or Gas Heat — Dehumidification (Hot Gas Reheat) Option (Downflow Only)
  • Unit Wiring with Cooling (no Electric Heat) or Gas Heat — Txv/Face-Split Evaporator Coil (Downflow Only)
  • Unit Wiring with Cooling (no Electric Heat) or Gas Heat — Standard Refrigeration System
  • Unit Wiring with Electric Heat (Single Point Connection) — Standard Refrigeration System (Downflow and Horizontal)
  • Unit Wiring with Electric Heat (Single Point Connection) — Txv/Face-Split Evaporator Coil or Dehumidification (Hot Gas Reheat) Refrigeration System (D
  • Electrical Characteristics — Compressor Motor and Condenser Motor 60 Cycle
  • Electrical Characteristics — Compressor Motor and Condenser Motor — 60 Cycle — Txv/Face-Split Evaporator Coil Option (Downflow Only)
  • Electrical Characteristics — Compressor Motor and Condenser Motor — 60 Cycle — Dehumidification (Hot Gas Reheat) Option (Downflow Only)
  • Electrical Characteristics — Evaporator Fan Motor — 60 Cycle — Standard and Oversized
  • Electrical Characteristics: Combustion Blower Motor (Gas/Electric)
  • Electrical Characteristics: Power Exhaust (Cooling and Gas/Electric)
  • Jobsite Connections
  • Cooling with Optional Electric Heat and Gas/Electric Models - 12½-17½ Tons Standard Efficiency; 12½ Tons High Efficiency
  • Cooling with Optional Electric Heat and Gas/Electric Models - 12½-17½ Tons Standard Efficiency; 12½ Tons High Efficiency - Downflow Unit Clearance
  • Cooling with Optional Electric Heat and Gas/Electric Models - 12½-17½ Tons Standard Efficiency; 12½ Tons High Efficiency - Horizontal Unit Supply/Return and Unit Clearance
  • Cooling with Optional Electric Heat and Gas/Electric Models 12½-17½ Tons Standard Efficiency - 12½ Tons High Efficiency - Roof Curb
  • Cooling with Optional Electric Heat and Gas/Electric Models 12½-17½ Tons Standard Efficiency; 12½ High Efficiency - Downflow Duct Connections - Field Fabricated
  • Cooling with Optional Electric Heat and Gas/Electric Models - 20-25 Tons Standard Efficiency; 15-25 Tons High Efficiency
  • Cooling with Optional Electric Heat and Gas/Electric Models - 20-25 Tons Standard Efficiency; 15-25 Tons High Efficiency - Unit Clearance and Horizontal Unit Supply/Return
  • Cooling with Optional Electric Heat and Gas/Electric Models - 20-25 Tons Standard Efficiency; 15-25 Tons High Efficiency - Roof Curb
  • Cooling with Optional Electric Heat and Gas/Electric Models - 20-25 Tons Standard Efficiency; 15-25 Tons High Efficiency - Downflow Duct Connections - Field Fabricated
  • Cooling with Optional Electric Heat and Gas/Electric Models - 20-25 Tons Standard Efficiency; 15-25 Tons High Efficiency - Downflow Unit Clearance
  • Standard Efficiency Units (Cooling and Gas/Electric)
  • High Efficiency Units (Cooling and Gas/Electric)
  • Cooling Unit - Swing Diameter & through the Base Electrical
  • Gas/Electric Unit - Swing Diameter & through the Base Electrical; Height of Gas Pipe (Second Drawing)
  • Fresh Air Hood (Horizontal Units) Diagram
  • Fresh Air Hood (Downflow Units) Diagram
  • Economizer - Horizontal Units Diagram
  • Economizer - Downflow Units Diagram
  • Maximum Unit & Corner Weights (Lbs) and Center of Gravity Dimensions (In.) Gas/Electric Heat Units Only
  • Accessory Net Weights (Lbs)
  • Factory Installed Options (FIOPS) Net Weights
  • Evaporator and Condenser Coils
  • Gas Heating Section
  • Factory Installed Options - Specifications
  • Factory or Field Installed Options - Specifications
  • Field Installed Options - Specifications
  • Economizer - Downflow
  • Digital Display Zone Sensor
  • Dual Thermistor Remote Zone Sensor
  • Motorized Outside Air Dampers
  • Powered Exhaust
  • Roof Curb - Downflow

Advertisement

Quick Links

  • 1 Model Number Description
  • 2 General Data — 12,5-15 Tons
  • Download this manual

Related Manuals for Trane Voyager TC*

Air Conditioner Trane Voyager Manual

Summary of Contents for Trane Voyager TC*

  • Page 1 Packaged Cooling & Gas/Electric Rooftops Voyager™ 12½-25 Tons — 60 Hz Packaged Cooling (TC*) Packaged Gas/Electric (YC*) RT-PRC024-EN May 2007...

Page 2: Introduction

Page 3: table of contents, page 4: features and benefits, page 5: standard features.

  • Page 6 Features and Benefits Our gas/electric rooftops exceed all Single Side Service Codes require a method of assured California seasonal efficiency unit shutdown for servicing. Field- Single side service is standard on all requirements and perform even installed disconnects sometimes units. better than the California NOx interfere with service access.
  • Page 7 Features and Benefits This option can only be ordered tight conduit and an external field Economizers are equipped with when Through the Base Electrical installed disconnect switch. either dry bulb or reference or with either the Disconnect Switch or comparative enthalpy sensing. These Factory provided through the base Circuit Breaker option is ordered.
  • Page 8 Because today’s owners are very adjust the minimum damper utilized with ReliaTel™ controls. cost-conscious when it comes to position. service and maintenance, the Trane Dual Thermistor Remote Zone Voyager was designed with direct Roof Curbs Sensor input from service contractors. This valuable information helped to Available for downflow units.
  • Page 9 Less money is Voyager units incorporate either a ReliaTel™ tied up in inventory with ReliaTel. one piece top or the Trane-Tite-Top The wiring of the low voltage ). Each part of the top (either two VariTrac – Building Automation...

Page 10: Factory Installed Options

Page 11: application considerations, page 12: selection procedure.

  • Page 13 Selection Procedure Dehumidification Selection Table 45 (airflow table for 20 ton Step 4: dehumidification units) indicates that Determine reheat temperature rise Note: Dehumidification selection a standard motor and drive is needed Using the leaving evaporator temp, procedure is the same for for this airflow and static pressure go to Table 59...

Page 14: Model Number Description

  • Page 15 Electrical and either either unit mounted disconnect 7,11,15 • Electric Heaters Unit Mounted Disconnect or or circuit breaker. When adding Circuit Breaker. heat, must order Trane Electric 3,4,7 • Frostat Heat. Available factory installed on • LonTalk® Communications downflow AND horizontal units.

Page 16: General Data

  • Page 17 General Data (12½,15 Tons Standard Efficiency) Table 1. (continued) General Data — 12½-15 Tons 12½ Tons Downflow & Horizontal Units 15 Tons Downflow & Horizontal Units (viii) Heating Performance (Gas/Electric Only) Heating Models High High Heating Input (Btuh) 150,000 250,000 250,000 350,000 1st Stage (Btu)
  • Page 18 General Data (17½, 20 Tons Standard Efficiency) Table 2. General Data — 17½-20 Tons 17½ Tons Downflow & Horizontal Units 20 Tons Downflow & Horizontal Units TC*210C3,4,W,K YC*210C3,4,WL/H,K TC*240B3,4,W,K YC*240B3,4,WL/H,K Cooling Performance Gross Cooling Capacity 210,000 210,000 242,000 242,000 (ii) EER (Downflow/Horizontal) Nominal CFM / ARI Rated CFM 7,000/5,800...
  • Page 19 General Data (17½, 20 Tons Standard Efficiency) Table 2. (continued) General Data — 17½-20 Tons 17½ Tons Downflow & Horizontal Units 20 Tons Downflow & Horizontal Units (viii) Heating Performance (Gas/Electric Only) Heating Models High High Heating Input (Btuh) 250,000 350,000 250,000 400,000...
  • Page 20 General Data (25 Tons Standard Efficiency) Table 3. General Data — 25 Tons 25 Tons Downflow & Horizontal Units T/YC*300B3,4,W(L,H (ii) Cooling Performance Gross Cooling Capacity 290,000 (iii) EER (Downflow/Horizontal) Nominal CFM / ARI Rated CFM 10,000/8,750 ARI Net Cooling Capacity 272,000 (iv) Integrated Part Load Value...
  • Page 21 General Data (25 Tons Standard Efficiency) Table 3. (continued) General Data — 25 Tons 25 Tons Downflow & Horizontal Units (ix) Heating Performance (Gas/Electric Only) Heating Models High Heating Input (Btuh) 250,000 400,000 1st Stage (Btu) 175,000 300,000 Heating Output (Btuh) 203,000 324,000 1st Stage (Btu)
  • Page 22 General Data (12½,15 Tons High Efficiency) Table 4. General Data — 12½-15 Tons 12½ Tons Downflow & Horizontal Units 15 Tons Downflow & Horizontal Units (ii) T/YC*151C3,4,W T/YC*181C3,4,W (iii) Cooling Performance Gross Cooling Capacity 154,000 189,000 (iv) 11.30 11.50 Nominal CFM / ARI Rated CFM 5,000/4,400 6,000/5,300 ARI Net Cooling Capacity...
  • Page 23 General Data (12½,15 Tons High Efficiency) Table 4. (continued) General Data — 12½-15 Tons 12½ Tons Downflow & Horizontal Units 15 Tons Downflow & Horizontal Units Heating Performance (Gas/Electric Only) Heating Models High High Heating Input (Btuh) 150,000 250,000 250,000 350,000 1st Stage (Btu) 100,000...
  • Page 24 General Data (17½, 20, 25 Tons High Efficiency) Table 5. General Data — 17½, 20, 25 Tons 17½ Tons Downflow & 20 Tons Downflow & 25 Tons Downflow & Horizontal Units Horizontal Units Horizontal Units T/YC*211C3,4,W T/YC*241C3,4,W T/YC*301C3,4,W (ii) Cooling Performance Gross Cooling Capacity 220,000 268,000...
  • Page 25 General Data (17½, 20, 25 Tons High Efficiency) Table 5. (continued) General Data — 17½, 20, 25 Tons 17½ Tons Downflow & 20 Tons Downflow & 25 Tons Downflow & Horizontal Units Horizontal Units Horizontal Units (ix) Heating Performance (Gas/Electric Only) Heating Models High High...

Page 26: Performance Data

  • Page 27 Performance Data (17½, 20 Tons Standard Efficiency) Table 8. Gross Cooling Capacities 17½ Tons Three Phase Standard Efficiency T/YC*210C3,4,W,K Ambient Temperature Air Ent Entering Wet Bulb Flow DB CFM (F) MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC 6300 75 195.0 171.0 213.0 127.0 224.0 83.3 182.0 164.0 206.0 124.0 219.0 80.1 169.0 158.0 195.0 119.0 213.0 76.1 155.0 151.0 181.0 113.0 204.0 71.8 80 200.0 200.0 214.0 157.0 226.0 114.0 191.0 191.0 207.0 156.0 221.0 112.0 180.0 180.0 196.0 153.0 214.0 110.0 168.0 168.0 183.0 147.0 205.0 106.0 85 211.0 211.0 217.0 188.0 229.0 140.0 204.0 204.0 209.0 188.0 223.0 139.0 195.0 195.0 199.0 186.0 216.0 139.0 184.0 184.0 187.0 182.0 206.0 137.0...
  • Page 28 Performance Data (25 Tons Standard Efficiency) Table 10. Gross Cooling Capacities 25 Tons Three Phase Standard Efficiency T/YC*300B3,4,W,K Ambient Temperature Entering Wet Bulb Flow DB CFM (F) MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC 9000 75 266 319 118 247 215...
  • Page 29 Performance Data (12½ Tons High Efficiency) Table 11. Gross Cooling Capacities 12½ Tons Three Phase Standard Refrigeration System High Efficiency T/YC*151C3,4,W Ambient Temperature Entering Wet Bulb Flow DB CFM (F) MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC 4500 75 137.0 116.0 157.0 90.2 166.0 60.8 127.0 110.0 151.0 87.1 163.0 58.5 116.0 105.0 140.0 82.3 158.0 55.8 106.0 99.7 128.0 80.6 152.0 52.8 80 140.0 139.0 158.0 111.0 167.0 82.9 130.0 130.0 151.0 109.0 164.0 80.8 122.0 122.0 141.0 104.0 159.0 77.8 114.0 114.0 128.0 98.5 152.0 74.6...
  • Page 30 Performance Data (12½ Tons High Efficiency) Table 12. Gross Cooling Capacities 12½ Tons Three Phase Dehumidification (Hot Gas Reheat) or TXV Option High Efficiency T/Y*D151C3,4,W Ambient Temperature Entering Wet Bulb Flow DB CFM (F) MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC 2500* 75 123.8 88.0 138.9 73.4 155.2 55.8 118.2 84.4 132.8 70.1 148.6 52.6 112.1 80.7 126.2 66.6 141.5 49.2 105.6 76.8 119.1 62.8 133.8 45.6 80 123.9 100.8 139.0 85.5 155.2 69.8 118.3 97.3 132.9 82.0 148.7 66.4 112.1 93.3 126.3 78.3 141.5 62.8 105.7 89.6 119.2 74.4 133.9 59.0...
  • Page 31 Performance Data (15 Tons High Efficiency) Table 13. Gross Cooling Capacities 15 Tons Three Phase Standard Refrigeration System High Efficiency T/YC*181C3,4,W Ambient Temperature Entering Wet Bulb Flow DB CFM (F) MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC 5400 75 172 205 75.2 159 138...
  • Page 32 Performance Data (15 Tons High Efficiency) Table 14. Gross Cooling Capacities 15 Tons Three Phase Dehumidification (Hot Gas Reheat) or TXV Option High Efficiency T/Y*D181C3,4,W Ambient Temperature Entering Wet Bulb Flow DB CFM (F) MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC 3000* 75 150.0 106.0 168.0 88.9 187.7 68.3 144.0 102.3 161.4 85.3 180.6 64.8 137.5 98.4 154.4 81.6 173.0 61.2 130.8 94.4 147.1 77.8 165.0 57.5 80 150.2 121.0 168.1 103.0 187.8 84.7 144.1 117.3 161.5 99.3 180.7 81.1 137.7 113.4 154.6 95.4 173.1 77.2 131.0 109.3 147.3 91.5 165.1 73.3...
  • Page 33 Performance Data (17½ Tons High Efficiency) Table 15. Gross Cooling Capacities 17½ Tons Three Phase Standard Refrigeration Option High Efficiency T/YC*211C3,4,W Ambient Temperature Entering Wet Bulb Flow DB CFM (F) MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC 6300 75 200.0 169.0 224.0 130.0 233.0 86.2 184.0 162.0 215.0 125.0 231.0 83.3 169.0 154.0 199.0 118.0 226.0 79.3 147.0 147.0 180.0 113.0 214.0 74.2 80 202.0 202.0 225.0 161.0 236.0 118.0 190.0 190.0 216.0 158.0 234.0 117.0 177.0 177.0 200.0 151.0 227.0 112.0 164.0 164.0 181.0 142.0 214.0 107.0...
  • Page 34 Performance Data (17½ Tons High Efficiency) Table 16. Gross Cooling Capacities 17½ Tons Three Phase TXV Option High Efficiency T/Y*D211C3,4,W Ambient Temperature Entering Wet Bulb Flow DB CFM (F) MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC 3500* 75 178.1 125.2 199.2 102.8 222.1 78.3 170.4 120.6 190.9 98.4 213.1 74.0 162.3 115.7 182.1 93.7 203.6 69.5 153.6 110.7 172.8 88.9 193.6 64.9 80 178.3 143.9 199.4 121.1 222.2 97.7 170.6 139.3 191.1 116.5 213.3 93.4 162.4 134.5 182.3 111.8 203.8 88.8 153.8 129.5 173.1 106.8 193.7 84.0...
  • Page 35 Performance Data (20 Tons High Efficiency) Table 17. Gross Cooling Capacities 20 Tons Three Phase Standard Refrigeration Option High Efficiency T/YC*241C3,4,W Ambient Temperature Entering Wet Bulb Flow DB CFM (F) MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC 7200 75 246 284 105 228 196...
  • Page 36 Performance Data (20 Tons High Efficiency) Table 18. Gross Cooling Capacities 20Tons Three Phase TXV Option High Efficiency T/Y*D241C3,4,W Ambient Temperature Entering Wet Bulb Flow DB CFM (F) MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC 4000* 75 208.5 149.1 233.3 122.6 260.1 94.5 199.6 143.8 223.6 117.3 249.8 89.3 190.1 138.1 213.4 111.9 238.6 84.0 180.0 132.3 202.5 105.8 226.9 78.5 80 208.7 171.1 233.4 144.4 260.2 117.1 199.9 165.6 223.8 139.1 249.8 111.8 190.4 159.9 213.6 133.4 238.7 106.3 180.4 153.9 202.7 127.6 226.9 100.7...
  • Page 37 Performance Data (20 Tons High Efficiency) Table 19. Gross Cooling Capacities 20Tons Three Phase Dehumidification (Hot Gas Reheat) Option High Efficiency T/Y*D241C3,4,W Ambient Temperature Entering Wet Bulb Flow DB CFM (F) MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC 4000* 75 197.5 138.9 222.3 116.0 249.8 89.2 188.8 133.4 213.0 110.6 239.6 83.8 179.7 127.6 203.1 105.0 228.8 78.3 170.1 121.7 192.6 99.2 217.3 72.5 80 197.7 159.2 222.6 135.8 249.8 111.4 189.0 153.7 213.3 130.3 239.6 105.8 180.0 147.9 203.4 124.6 228.8 100.1 170.4 141.9 193.0 118.7 217.4 94.2...
  • Page 38 Performance Data (25 Tons High Efficiency) Table 20. Gross Cooling Capacities 25 Tons Three Phase Standard Refrigeration System High Efficiency T/YC*301C3,4,W Ambient Temperature Entering Wet Bulb Flow DB CFM (F) MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC 9000 75 277 316 117 258 234...
  • Page 39 Performance Data (25 Tons High Efficiency) Table 21. Gross Cooling Capacities 25 Tons Three Phase TXV Option High Efficiency T/Y*D301C3,4,W Ambient Temperature Entering Wet Bulb Flow DB CFM (F) MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC 5000* 75 241.0 176.5 269.7 142.7 300.9 107.2 229.7 169.7 257.6 135.9 287.8 100.8 217.8 162.6 244.9 129.0 274.0 94.1 205.5 155.3 231.6 122.0 259.8 87.3 80 241.4 204.6 269.9 170.5 300.9 135.9 230.2 197.7 257.8 163.8 287.8 129.3 218.4 190.5 245.1 156.8 274.1 122.5 206.2 183.2 231.9 149.6 259.8 115.6...
  • Page 40 Performance Data Table 22. Evaporator Fan Performance 12½ Tons TC*150D Downflow or Horizontal External Static Pressure (Inches of Water) 1.00 3-HP Standard Motor & Field Supplied Low Static Drive 3-HP Standard Motor & Sheaves 4000 — — — — — —...
  • Page 41 Performance Data (12½ Tons Standard Efficiency) Table 23. Evaporator Fan Performance 12½ Tons with Gas Heat YC*150D Downflow or Horizontal External Static Pressure (Inches of Water) 1.00 3-HP Standard Motor & Field Supplied Low Static Drive 3-HP Standard Motor & Drive 4000 —...
  • Page 42 Performance Data (15 Tons Standard Efficiency) Table 24. Evaporator Fan Performance 15 Tons TC*180B Downflow or Horizontal External Static Pressure (Inches of Water) 1.00 3-HP Standard Motor & Field Supplied Low Static Drive 3-HP Standard Motor & Sheaves 4800 — —...
  • Page 43 Performance Data (15 Tons Standard Efficiency) Table 25. Evaporator Fan Performance 15 Tons with Gas Heat YC*180B Downflow or Horizontal External Static Pressure (Inches of Water) 1.00 3-HP Standard Motor & Field Supplied Low Static Drive 3-HP Standard Motor & Sheaves 4800 —...
  • Page 44 Performance Data (17½ Tons Standard Efficiency) Table 26. Evaporator Fan Performance 17½ Tons TC*210C Downflow or Horizontal External Static Pressure (Inches of Water) 1.00 5-HP Standard Motor with Low Static Drive Accessory 5-HP Standard Motor & Sheaves 5600 — — —...
  • Page 45 Performance Data (17½ Tons Standard Efficiency) Table 27. Evaporator Fan Performance 17½ Tons with Gas Heat YC*210C Downflow or Horizontal External Static Pressure (Inches of Water) 1.00 5-HP Standard Motor & Low Static Drive Accessory 5-HP Standard Motor & Drive 5600 —...
  • Page 46 Performance Data (20 Tons Standard Efficiency) Table 28. Evaporator Fan Performance 20 Tons TC*240B Downflow or Horizontal External Static Pressure (Inches of Water) 1.00 5-HP Standard Motor with Low Static Drive 5-HP Standard Motor & Sheaves 6400 — — 1.69 1.88 2.05 2.21...
  • Page 47 Performance Data (20 Tons Standard Efficiency) Table 29. Evaporator Fan Performance 20 Tons with Gas Heat YC*240B Downflow or Horizontal External Static Pressure (Inches of Water) 1.00 5-HP Standard Motor & Field Supplied Low Static Drive 5-HP Standard Motor & Drive 6400 1.56 1.72...
  • Page 48 Performance Data (25 Tons Standard Efficiency) Table 30. Evaporator Fan Performance 25 Tons TC*300B Downflow or Horizontal External Static Pressure (Inches of Water) 1.00 7.5-HP Standard Motor & Low Static Drive Accessory 7.5-HP Standard Motor & Sheaves 7000 — — —...
  • Page 49 Performance Data (25 Tons Standard Efficiency) Table 31. Evaporator Fan Performance 25 Tons with Gas Heat YC*300B Downflow or Horizontal External Static Pressure (Inches of Water) 1.00 7.5-HP Standard Motor & Low Static Drive Accessory 7.5-HP Standard Motor & Drive 7000 —...
  • Page 50 Performance Data (12½ Tons High Efficiency) Table 32. Evaporator Fan Performance 12½ Tons TCD151C Standard or TXV Refrigeration System Downflow External Static Pressure (Inches of Water) 1.00 3-HP Standard Motor & Field Supplied Low Static Drive 3-HP Standard Motor & Drive 2500* —...
  • Page 51 Performance Data (12½ Tons High Efficiency) Table 33. Evaporator Fan Performance 12½ Tons T*D151C Dehumidification (Hot Gas Reheat Option) Downflow External Static Pressure (Inches of Water) 1.00 3-HP Standard Motor & Drive w/Field Supplied Low Static Drive Fan Sheave 3-HP Standard Motor & Drive 2500* —...
  • Page 52 Performance Data (12½ Tons High Efficiency) Table 34. Evaporator Fan Performance 12½ Tons TCH151C Standard Refrigeration System Horizontal External Static Pressure (Inches of Water) 1.00 3-HP Standard Motor & Field Supplied Low Static Drive 3-HP Standard Motor & Drive 4000 —...
  • Page 53 Performance Data (12½ Tons High Efficiency) Table 35. Evaporator Fan Performance 12½ Tons with Gas Heat YCD151C Standard or TXV Refrigeration System Downflow External Static Pressure (Inches of Water) 1.00 3-HP Standard Motor & Field Supplied Low Static Drive 3-HP Standard Motor & Drive 4000 —...
  • Page 54 Performance Data (12½ Tons High Efficiency) Table 36. Evaporator Fan Performance 12½ Tons with Gas Heat Y*D151C Dehumidification (Hot Gas Reheat Option) Downflow External Static Pressure (Inches of Water) 1.00 3-HP Standard Motor & Drive 3-HP Standard Motor & High Static Drive Accessory 4000 1.12 1.25...
  • Page 55 Performance Data (12½ Tons High Efficiency) Table 37. Evaporator Fan Performance 12½ Tons with Gas Heat YCH151C Standard Refrigeration System Horizontal External Static Pressure (Inches of Water) 1.00 3-HP Standard Motor & Field Supplied Low Static Drive 3-HP Standard Motor & Drive 4000 —...
  • Page 56 Performance Data (15 Tons High Efficiency) Table 38. Evaporator Fan Performance 15 Tons TC*181C Standard or TXV Refrigeration System Downflow or Horizontal External Static Pressure (Inches of Water) 1.00 3-HP Standard Motor & Field Supplied Extra Low Static Drive 3-HP Standard Motor & Field Supplied Low Static Drive 3000* —...
  • Page 57 Performance Data (15 Tons High Efficiency) Table 39. Evaporator Fan Performance 15 Tons T*D181C Dehumidification (Hot Gas Reheat Option) Downflow External Static Pressure (Inches of Water) 1.00 3-HP Standard Motor w/ 3-HP Standard Motor 3-HP Standard Motor Field Supplied Motor w/Field Supplied Motor w/Field Supplied Low (ii)
  • Page 58 Performance Data (15 Tons High Efficiency) Table 40. Evaporator Fan Performance 15 Tons with Gas Heat YC*181C Standard or TXV Refrigeration System Downflow or Horizontal External Static Pressure (Inches of Water) 1.00 3-HP Standard Motor & Field Supplied Low Static Drive 3-HP Standard Motor &...
  • Page 59 Performance Data (15 Tons High Efficiency) Table 41. Evaporator Fan Performance 15 Tons with Gas Heat Y*D181C Dehumidification (Hot Gas Reheat) Option Downflow External Static Pressure (Inches of Water) 1.00 3-HP Standard Motor & Field Supplied Low Static Drive 3-HP Standard Motor & Drive 4800 0.88 1.03...
  • Page 60 Performance Data (17½ Tons High Efficiency) Table 42. Evaporator Fan Performance 17½ Tons TC*211C Standard or TXV Refrigeration System Downflow or Horizontal External Static Pressure (Inches of Water) 1.00 (ii) 5-HP Standard Motor & Field Supplied Extra Low Static Drive 5-HP Standard Motor &...
  • Page 61 Performance Data (17½ Tons High Efficiency) Table 43. Evaporator Fan Performance 17½ Tons with Gas Heat YC*211C Standard or TXV Refrigeration System Downflow or Horizontal External Static Pressure (Inches of Water) 1.00 5-HP Standard Motor & Field Supplied Low Static Drive 5-HP Standard Motor &...
  • Page 62 Performance Data (20 Tons High Efficiency) Table 44. Evaporator Fan Performance 20 Tons TC*241C Standard or TXV Refrigeration System Downflow or Horizontal External Static Pressure (Inches of Water) 1.00 (ii) 5-HP Standard Motor & Field Supplied Extra Low Static Drive 5-HP Standard Motor &...
  • Page 63 Performance Data (20 Tons High Efficiency) Table 45. Evaporator Fan Performance 20 Tons T*D241C Dehumidification (Hot Gas Reheat Option) Downflow External Static Pressure (Inches of Water) 1.00 5-HP Standard Motor & Field Supplied 5-HP Standard Motor & Drive & Field 5-HP Standard Motor &...
  • Page 64 Performance Data (20 Tons High Efficiency) Table 46. Evaporator Fan Performance 20 Tons with Gas Heat YC*241 Standard or TXV Refrigeration System Downflow or Horizontal External Static Pressure (Inches of Water) 1.00 5-HP Standard Motor & Field Supplied Low Static Drive 5-HP Standard Motor &...
  • Page 65 Performance Data (20 Tons High Efficiency) Table 47. Evaporator Fan Performance 20 Tons with Gas Heat Y*D241 Dehumidification (Hot Gas Reheat Option) Downflow External Static Pressure (Inches of Water) 1.00 5-HP Standard Motor & Field Supplied Low Static Drive 5-HP Standard Motor & Drive 6400 1.92 2.14...
  • Page 66 Performance Data (25 Tons High Efficiency) Table 48. Evaporator Fan Performance 25 Tons TC*301C Standard Refrigeration or TXV System Downflow or Horizontal External Static Pressure (Inches of Water) 1.00 7.5-HP Standard Motor & Field Supplied Extra Low Static Drive 7.5-HP Standard Motor & Low Static Drive Accessory 5000* —...
  • Page 67 Performance Data (25 Tons High Efficiency) Table 49. Evaporator Fan Performance 25 Tons with Gas Heat YC*301C Standard Refrigeration or TXV System Downflow or Horizontal External Static Pressure (Inches of Water) 1.00 7.5-HP Standard Motor & Low Static Drive Accessory 7.5-HP Standard Motor Drive 8000 3.29...
  • Page 68 Performance Data Table 50. Standard Motor & Drive/Fan Speed (Rpm) Unit Model 6 Turns 5 Turns 4 Turns 3 Turns 2 Turns 1 Turn Tons Number Open Open Open Open Open Open Closed 12½ T/YC*150D3,4,W, YC*151C3,4,W T/YC*150DK T/YC*180B3,4,W T/YC*180BK T/YC*181C3,4,W 17½...
  • Page 69 Performance Data Table 54. Static Pressure Drop Through Accessories (Inches Water Column) Economizer with Electric Heater (ii) OA/RA Dampers Accessory (kW) Unit Model Standard Through 2" Pleated 100% 100% 5-12 14-27 (iii) (iv) Tons Number Filters Reheat Coil Filter 12½ T/Y*150D,T/YC*151C **2500 0.02 0.01 0.03...
  • Page 70 Performance Data Table 55. Gas Fired Heating Capacities Unit Model Heating Heating Air Temp. (ii) Tons Number Input MBH Output MBH Rise, F 12½ YC*150D-L1, YC*151C-L1 150/100 122/81 10-40 YC*150D-H1,YC*151C-H1 250/175 203/142 25-55 YC*180B-L1 250/175 203/142 25-55 YC*180B-H1,YC*181C-H1 350/250 284/203 35-65 YC*181C-L1 250/175...
  • Page 71 Performance Data Table 58. Air Temperature Rise Across Electric Heaters (Degrees F) 12½ Tons 15 Tons 17½ Tons 20 Tons 25 Tons 5000 CFM 6000 CFM 7000 CFM 8000 CFM 9000 CFM Stages Three Phase Three Phase Three Phase Three Phase Three Phase TC*150/151 TC*180/181...

Page 72: Controls

  • Page 73 Two Heat/Two Cool programmable Three Heat, Two Cool digital display processor interface allows the unit to thermostat with touch screen digital thermostat. Easy access battery communicate to Trane’s Integrated display. Menu-driven programming. replacement. Flip-out door for easy Comfort system. Effortless set-up. Program each day...

Page 74: Electrical Data

  • Page 75 Electrical Data (Standard Efficiency) Table 61. Unit Wiring with Electric Heat (Single Point Connection) — Standard and Oversized Motor, Downflow & Horizontal Standard Indoor Motor Oversize Indoor Motor Max Fuse Size Max Fuse Size Unit Model Heater Model Heater kW Control or Max Circuit or Max Circuit...
  • Page 76 Electrical Data (Standard Efficiency) Table 61. (continued) Unit Wiring with Electric Heat (Single Point Connection) — Standard and Oversized Motor, Downflow & Horizontal Standard Indoor Motor Oversize Indoor Motor Max Fuse Size Max Fuse Size Unit Model Heater Model Heater kW Control or Max Circuit or Max Circuit...
  • Page 77 Electrical Data (Standard Efficiency) Table 63. Electrical Characteristics — Evaporator Fan Motor — 60 Cycle — Standard and Oversized Motor Standard Evaporator Fan Motor Oversized Evaporator Fan Motor Amps Amps Unit Model Tons Number Volts Phase Volts Phase 12½ T/YC*150D3 208-230 3.00 10.6...
  • Page 78 Electrical Data (High Efficiency) Table 66. Unit Wiring with Cooling (No Electric Heat) or Gas Heat — Standard Refrigeration System Standard Indoor Fan Motor Oversize Indoor Fan Motor Maximum Fuse Maximum Fuse Unit Model Unit Operating Minimum Circuit Size or Maximum Minimum Circuit Size or Maximum Tons...
  • Page 79 Electrical Data (High Efficiency) Table 69. Unit Wiring with Electric Heat (Single Point Connection) — Standard Refrigeration System (Downflow and Horizontal) Standard Indoor Motor Oversize Indoor Motor Max Fuse Size Max Fuse Size Unit Model Heater Model Heater kW Control or Max Circuit or Max Circuit Tons...
  • Page 80 Electrical Data (High Efficiency) Table 70. Unit Wiring with Electric Heat (Single Point Connection) — TXV/Face-Split Evaporator Coil or Dehumidification (Hot Gas Reheat) Refrigeration System (Downflow only) Standard Indoor Motor Oversize Indoor Motor Max Fuse Size Max Fuse Size Unit Model Heater Model Heater kW Control...
  • Page 81 Electrical Data (High Efficiency) Table 70. (continued) Unit Wiring with Electric Heat (Single Point Connection) — TXV/Face-Split Evaporator Coil or Dehumidification (Hot Gas Reheat) Refrigeration System (Downflow only) Standard Indoor Motor Oversize Indoor Motor Max Fuse Size Max Fuse Size Unit Model Heater Model Heater kW...
  • Page 82 Electrical Data (High Efficiency) Table 73. Electrical Characteristics — Compressor Motor and Condenser Motor — 60 Cycle — Dehumidification (Hot Gas Reheat) Option (Downflow Only) Compressor Motors Condenser Fan Motors Amps Amps Unit Model (ii) Tons Number Volts Phase Phase 12½...

Page 83: Jobsite Connections

Page 84: typical wiring.

  • Page 85 Typical Wiring (12½-25 Tons Cooling with Optional Electric Heat) Figure 3. (continued from previous page)12.5-25 Tons Cooling with Optional Electric Heat - for specific wiring, see service facts. RT-PRC024-EN...
  • Page 86 Typical Wiring (12½-25 Tons Cooling with Optional Electric Heat) Figure 4. 12.5-25 Tons Cooling with Optional Electric Heat - for specific wiring, see service facts. RT-PRC024-EN...
  • Page 87 Typical Wiring (12½-25 Tons Cooling with Optional Electric Heat) Figure 4. (continued from previous page)12.5-25 Tons Cooling with Optional Electric Heat - for specific wiring, see service facts. RT-PRC024-EN...
  • Page 88 Typical Wiring (12½-25 Tons Gas/Electric) Figure 5. 12.5-25 Tons Gas/Electric- for specific wiring, see service facts. RT-PRC024-EN...
  • Page 89 Typical Wiring (12½-25 Tons Gas/Electric) Figure 5. (continued from previous page)12.5-25 Tons Gas/Electric - for specific wiring, see service facts. RT-PRC024-EN...
  • Page 90 Typical Wiring (12½-25 Tons Gas/Electric) Figure 6. 12.5-25 Tons Gas/Electric- for specific wiring, see service facts. RT-PRC024-EN...
  • Page 91 Typical Wiring (12½-25 Tons Gas/Electric) Figure 6. (continued from previous page)12.5-25 Tons Gas/Electric- for specific wiring, see service facts. RT-PRC024-EN...

Page 92: Dimensional Data

  • Page 93 Dimensional Data (Standard and High Efficiency) Figure 9. Cooling with Optional Electric Heat and Gas/Electric Models 12½-17½ Tons Standard Efficiency - 12½ Tons High Efficiency - Roof Curb * All dimensions are in inches/millimeters. 26 5/16 Figure 10. Cooling with Optional Electric Heat and Gas/Electric Models 12½-17½ Tons Standard Efficiency;...
  • Page 94 Dimensional Data (Standard and High Efficiency) 2138 MM Figure 12. Cooling with Optional Electric Heat and Gas/Electric Models - 20-25 Tons Standard Efficiency; 15-25 Tons High Efficiency * All dimensions are in inches/millimeters. Figure 13. Cooling with Optional Electric Heat and Gas/Electric Models - 20-25 Tons Standard Efficiency;...
  • Page 95 Dimensional Data (Standard and High Efficiency) Figure 14. Cooling with Optional Electric Heat and Gas/Electric Models - 20-25 Tons Standard Efficiency; 15-25 Tons High Efficiency - Roof Curb * All dimensions are in inches/millimeters. Figure 15. Cooling with Optional Electric Heat and Gas/Electric Models - 20-25 Tons Standard Efficiency;...
  • Page 96 Dimensional Data (12½-25 Tons) Table 78. Standard Efficiency Units (Cooling and Gas/Electric) Condensate Condensate Drain Location Tons Downflow Only Drain Size Downflow Horizontal 12½, 15, 17½ 26 7/16 22 1/2 18 11/16 4 1/4 4 1/4 62 7/16 54 11/16 1 NPT 25 5/8 20, 25...
  • Page 97 Dimensional Data (12½-25 Tons) Table 80. Unit Model # TCD150, 151, 180, 210 42 3/8 48 3/8 TCD181, 211-301 29 1/2 38 1/2 18 1/2 All dimensions are in inches. TOP VIEW SHOWING THROUGH THE BASE ELECTRICAL UTILITY LOCATIONS AND ACCESS PANEL SWING CLEARANCES. 6 7/8"...
  • Page 98 Dimensional Data (12½-25 Tons Accessories) FRESH AIR HOOD (MANUAL) HORIZONTAL UNITS 19 ½” Figure 22. Economizer - Horizontal Units Figure 19. Fresh Air Hood (Horizontal Units) Note: When applying economizer to horizontal units, connected ductwork must be run full size to allow proper operation of economizer damper.

Page 99: Weights

  • Page 100 Weights (12½-25 Tons) (ii) Table 85. Accessory Net Weights (Lbs) Unit Economizer Outside Air Damper Power Roof Oversized High Static Low Static (iii) (iv) (vi) Model No. Manual Motorized Exhaust Curb Motor Adder Drive Drive Conversion Kit T/YCD150D,180B T/YCD151C, TCD210C T/YCD240B T/YCD181,211,241C —...
  • Page 101 Weights (12½-25 Tons) (ii) (iii) Table 87. Factory Installed Options (FIOPS) Net Weights Accessory Weight Unit Model Number (iv) High Efficiency Motors T/YC*150-181 standard size motor T/YC*210-241 standard size motor T/YC*150-181 oversize motor T/YC*210-241 oversize motor T/YC*300-301 standard size motor Hinged Doors All T/YC* units Powered Convenience Outlet...

Page 102: Mechanical Specifications

  • Page 103 Mechanical Specifications Controls High Efficiency Motors Through the Base Electrical with Circuit Breaker Unit shall be completely factory This option is available with wired with necessary controls and efficiency ratings from 86.5 up to This option is a thermal magnetic, contactor pressure lugs or terminal 91.0.
  • Page 104 The fan failure switch will disable all ReliaTel™ controlled units with the unit functions and "flash" the Service Frostat Trane Integrated Comfort™ systems. LED on the zone sensor. The dirty This option is to be utilized as a filter switch will light the Service LED Field Installed Options safety device.
  • Page 105 Mechanical Specifications Dual Thermistor Remote Zone Remote Potentiometer Sensor The minimum position setting of the economizer shall be adjusted with This sensor will allow the customer this accessory. to reduce the total number of remote sensors to obtain space temperature Ventilation Override Accessory averaging.
  • Page 108 Trane A business of American Standard Companies www.trane.com Trane has a policy of continuous product and product data improvement and reserves the right to change design and specifications without notice. For more information, contact your local Trane office or e-mail us at [email protected]...

This manual is also suitable for:

Rename the bookmark, delete bookmark, delete from my manuals, upload manual.

IMAGES

  1. Trane Voyager 12.5 to 25 Tons Catalogue

    trane voyager 3 dimensions

  2. Trane Cabinet Unit Heater Revit

    trane voyager 3 dimensions

  3. Trane Voyager Rooftop Units

    trane voyager 3 dimensions

  4. Trane Voyager Rooftop Units

    trane voyager 3 dimensions

  5. Купить Trane voyager iii у официального дилера в РФ

    trane voyager 3 dimensions

  6. Comfort Temp Heating & Cooling, Packaged Heating and Air Conditioning

    trane voyager 3 dimensions

VIDEO

  1. Trane Voyager commercial gas pack

  2. Trane Voyager igniter replacement

  3. Grand Design Momentum 23G Toy Hauler Travel Trailer

  4. AIRCOOLED CHILLER TRANE CGAM 110

  5. Alliance Valor 31T13 / RV Experts Crown Best Travel Trailer Toy Hauler for 2023

  6. Unleash the Extra Mile: Titan Vans 3-Year Warranty!

COMMENTS

  1. PDF Voyager™ III Rooftop Units

    Figure 3 - TD5 service and diagnostic user display The TD-5 display allows you to view data and make operational changes on Voyager rooftop equipped with Reliatel control v3.4 or above. TD-5 is an 5" (127mm diagonal) high resolution color touch screen display TD-5 provides in 26 languages: 15 different reports (3 custom, 12 standard)

  2. PDF Quick Reference Guide Voyager™ 12.5 to 25 Tons Packaged Rooftop Units

    Voyager™ 12.5 to 25 Tons Packaged Rooftop Units ... Ingersoll Rand , Thermo King and Trane ... 575/3 380/3 Table 6. Unit dimensional data BC C+ Unit Length UL 106 11/16 122 5/16 122 5/16 Unit Width UW 70 13/16 84 3/16 84 3/16 Unit Height UH 52 1/4 56 1/8 66 1/4 Clearance C1 60 60 60 Clearance C2 48 48 48

  3. Voyager

    Voyager 2 - 12.5 - 25 Tons Voyager 3 - 27.5 - 50 Tons . We know time is money. You can have your Voyager unit in two to three weeks - the fastest delivery in the industry - to help keep projects on track and get job sites up and running quickly. Choose from Voyager 2 or Voyager 3 models to meet the needs of a broad range of small, medium to large commercial buildings.

  4. PDF Product Catalog

    Trane delivers with Voyager. Voyager features cutting edge technologies: reliable compressors, Trane engineered ReliaTel controls, computer-aided run testing, and Integr ated Comfort™ Systems. So, whether you're the contractor, the engineer, or the owner, you can be certain Voyager products are built to meet your needs. Trademarks

  5. PDF Voyager™ II Rooftop Units

    at 1.4 MPa and pressure tested to 3.1 MPa. † Every unit and its options receive a 100% unit run test before leaving the production line to make sure it lives up to Trane r equirements. Ease Of Installation Voyager units provide many time and money saving features. Conversionless Units † The dedicated design units (either downfl ow or

  6. PDF Installation, Operation, and Maintenance Voyager™ 3

    6 RT-SVX34W-EN Model Number Description 60 Hz Description Digit 1, 2 — Unit Function TC = DX Cooling, No Heat TE = DX Cooling, Electric Heat YC = DX Cooling, Natural Gas Heat

  7. PDF Installation, Operation, and Maintenance Voyager™ 3

    E = 208/60/3 F = 230/60/3 4 = 460/60/3 5 = 575/60/3 Digit 9 — Heating Capacity2 0 = No Heat (TC Only) L = Low Heat (YC Only) H = High Heat (YC Only) J = Low Heat-Stainless Steel Gas Heat Exchanger (YC Only) K = High Heat-Stainless Steel Gas Heat Exchangers (YC Only) M = Low Heat-Stainless Steel Gas Heat Exchanger w/ Modulating Control (27.5 ...

  8. TRANE TECHNOLOGIES VOYAGER 3 INSTALLATION, OPERATION AND ...

    View and Download Trane Technologies Voyager 3 installation, operation and maintenance manual online. Packaged Rooftop Air Conditioners with Symbio 700 Controls. Voyager 3 air conditioner pdf manual download. ... Page 13 Unit Dimensions and Weights Figure 3. 60 Hz 27.5-35, 50 Hz 23-29 tons (TC, TE, YC low heat) NOTES: 1. SEE DETAIL HOOD DRAWING ...

  9. TRANE VOYAGER MANUAL Pdf Download

    View and Download Trane Voyager manual online. Product. Voyager air conditioner pdf manual download. ... Page 1 YC-D-7 October 1996 Packaged Gas/Electric Rooftop Units Voyager™ 3 through 25 Tons — 60 ... Page 86 Dimensional 3-25 Ton Data Table 86-1 Standard Efficiency Units Condensate Drain Location Condensate Drain Location Condensate ...

  10. Products-Unitary Rooftop Systems-Voyager III

    The Voyager™ Commercial line offers 27½ to 50 ton, 60 Hz and 23 to 42 ton 50 Hz models. Both 50 and 60 Hz models come in a choice of five sizes to meet the changing demands of the commercial rooftop market. Trane customers demand products that provide exceptional reliability, meet stringent performance requirements, and are competitively ...

  11. PDF Voyager™ III Rooftop Units

    Dimensions, weights and clearances 25 Weights of factory-installed accessories 26 Controls 28 Equipment protection/operation 27 ... † The Trane Voyager Rooftop has, by far, the best COP in its class. All performances are Eurovent certified which provides the assurance of accurate

  12. PDF System Catalog Zoned Rooftop Systems

    Specifications p. 42 interface on a 10-inch touchscreen display, ... 3 Components of a Trane® Zoned Rooftop System This catalog pertains to Trane® Precedent® or Voyager® 3 rooftops with Symbio® controls. (For rooftops with ReliaTel® controls, see the previous version of this catalog, APP-PRC005J-EN.) ...

  13. PDF Quick Reference Guide Voyager™ 12½-25 Ton Packaged Rooftop Units

    (a)Dimensions are for curb openings and not duct inserts. Reference the product catalog for duct insert dimensions. 28 1/2 28 9/16 28 9/16 Supply Width SW(a) 55 1/2 69 1/2 69 1/2 Return Length RL(a) 20 7/8 22 1/4 22 1/4 Return Width RW(a) 63 77 77 RW RL SW SL CW CL UL UW UH

  14. Rooftop Units

    IntelliPak rooftop units set the bar for durability and value. With a portfolio of three distinct products and industry leading efficiencies, the Intellipak product is designed to serve a range of application and regulatory needs. IntelliPak 1 - 20-130 Tons. IntelliPak 2 - 90-150 Tons. IntelliPak 3 - 20-75 Tons.

  15. Voyager 3 w/ Symbio 700 User Guide

    Voyager 3 w/ Symbio 700 User Guide. and protection of the equipment. It offers equipment and control configurations that can be used with. light commercial packaged equipment. This control system consists of the Symbio 700 main controller. and up to four option modules used to provide optional functional operation. A system may or may not.

  16. TRANE VOYAGER YS 150-300 INSTALLATION, OPERATION AND ...

    Page 1 Installation, Operation, and Maintenance Packaged Rooftop Air Conditioners Voyager™ Gas/ Electric - 12½ - 25 Tons, 60/50Hz Model Number: YS*150-300 YH*150-300 SAFETY WARNING Only qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating, and air ...

  17. TRANE VOYAGER YH SERIES INSTALLATION, OPERATION AND ...

    View and Download Trane Voyager YH Series installation, operation and maintenance manual online. Packaged Rooftop Air Conditioners - Cooling, Gas/Electric 12.5 to 25 Tons, 60/50Hz. ... Figure 6. Unit dimensional data 15-25 tons high efficiency units Note: ½ NPT Gas Connection Figure 7. Unit dimensional data 15-25 tons standard efficiency ...

  18. Packaged Rooftop Air Conditioners Voyager Cooling and Gas ...

    Voyager continues to provide the highest standards in quality and reliability, comfort, ease of service, and the performance of Trane light commercial products. Trane customers demand products that provid e exceptional reliability, meet stringent performance requirements, and are competitively priced. Trane delivers with Voyager.

  19. PDF Voyager™ II Rooftop Units

    Dimensions and Weights 19 Controls 20 Mechanical Specifications 24 RT-PRC014-E4_1112:BAT2 30.5.2013 11:01 Page 3 ... • Voyager units incorporate the Trane-Tite-Top (T3 ). Each part of the top (three pieces) overlaps in such a way that water cannot leak into the unit.

  20. Trane® Voyager 12.5 to 50 Ton Commercial HVAC Rooftop Units

    Voyager® 2 - 12.5 - 25 Tons & Voyager® 3 27.5 - 50 Tons. Key Features: Available in gas/electric, electric/electric & heat pump only for Voyager 2. Dependable MERV filtration that removes contaminants as small as 0.3 microns. Fast delivery to keep projects on track and sites up and running. Energy-efficient performance lowers costs ...

  21. TRANE VOYAGER TC* USER MANUAL Pdf Download

    View and Download Trane Voyager TC* user manual online. Packaged Cooling & Gas/Electric Rooftops 12 1/2-25 Tons — 60 Hz. ... When adding Circuit Breaker. heat, must order Trane Electric 3,4,7 • Frostat Heat. Available factory installed on • LonTalk® Communications downflow AND horizontal units. ... Dimensional Data 1819 MM 50 1/8 1229 MM ...